Maxum I HVLP Spray Gun Adjustments
Air Control Valve
Material Flow
Adjustment
External Packing Nut
One-Way Valve
To produce the highest-quality finish possible, the spray gun requires the
proper air and material adjustments. You control the air flow with the air
control valve, located at the rear of the gun.
Note the notch that is cast into the control knob on the valve. Air flow is at its
fullest when the knob is set at the 12:00 position. Rotating the valve 180° either
direction cuts off the air.
The air control valve is used when spraying with light viscosity materials or
in confined areas, such as cabinets or lockers. When spraying light material,
full air is not needed. Restrict the valve until you achieve proper atomization
without excess overspray.
The amount of paint fed
from the cup out the nozzle
is controlled by the material
adjustment knob located at
the heel of the gun, just above
the handle. To decrease paint
flow, turn the fluid
adjustment knob clockwise.
To increase the paint flow,
turn the knob
counter-clockwise. A little
experimentation will give
you the correct combination
of paint and air necessary
to achieve the desired finish
and fan size. The material
adjustment can also be used to set a specific trigger pull, so the same pattern
size and material flow are consistently obtained on each pass.
The external packing nut, located directly in front of the trigger, is used to
adjust the packing so a seal is maintained around the needle.
The one-way valve, or
serviceable check valve, is
designed to allow air into the
cup, putting the material under
pressure, yet not releasing the
cup pressure. CAPspray‘s
one-way valve prevents paint
from seeping up the air tube
into the air passages of the gun.
It also eliminates any delay in
material flow when the gun
is triggered.
CAPspray‘s one-way valve is
easily detached for cleaning purposes. The valve simply rotates to open for
cleaning and contains a disk that can be removed and cleaned with soap and
water for waterborne materials or a compatible solvent for other materials.
MAX
Maximum Air Flow
Minimum
Air Flow
Minimum
Air Flow
Material flow
Air control
Packing Nut
9
Vue de la page 10