Section F.) and should check other menu settings before
testing to assure that previously selected values are as
desired. The FDV cannot be shut off in this mode until a value
for "LoAd" has been selected.
NOTE: Force Cell Modules in the 1 and 2 lb capacities are not available.
6. (SCAL)
NO USER ACCESS
7. RS232 Output (232)
The FDV Force Gage features an RS232 computer interface output,
allowing the user to connect the gage to an IBM compatible com-
puter. The RS232 output is enabled or disabled by selecting one of
the following options:
232E Enable RS232 output
232d Disable RS232 output
8. Mitutoyo Output (tut)
The FDV also features a modified BCD output that is compatible with
Mitutoyo printers. The Mitutoyo is enabled or disabled by selecting
one of the following options:
tutE Enable Mitutoyo output
tutd Disable Mitutoyo output
9. Calibration (CAL)
It is most important that the FDV Digital Force Gage is tested periodi-
cally to confirm its accuracy. For a detailed procedure see Section H.